Find your setup

Appliance wattage chart — audited, not copied

130 appliances with running watts and startup surge, every value traceable to U.S. DOE data, the ENERGY STAR certified-product datasets, or manufacturer spec sheets. Before publishing it, we machine-checked the internet's most-copied wattage table against those sources and found 25 corrections and withdrawals. They are documented below — judge the data, not the marketing.

The audit: what the copied table gets wrong

The wattage table most sites republish traces back decades. Checking it against primary sources produced corrections in both directions — and both cost you money: understated startup loads make a generator or battery station trip offline the first time a motor starts; overstated loads make you buy twice the capacity you need.

Understated — your station trips offline (corrected up)

ApplianceCopied tableAuditedBasis
Refrigerators & freezers (7 models)startup surge 375–660W1,200Wcompressor LRA physics (nameplate reports, 9–12× RLA)
RV rooftop AC (13.5K)startup 7,200W7,800VADometic install manual LRA 68A
Garbage disposal (½HP)450W750WInSinkErator Badger 5 spec 6.3A
Espresso machine (pump class)800W1,300WDe'Longhi 1100W / Breville 1560W official
Circular saw (corded 7¼")900W1,500W15A rated class (Makita/DeWalt)
Corded drill (½")750W850W7.0–7.8A rated class
Band saw (14")1,100W / 1,400WUnconfirmed WCurrent-only conversion withdrawn
String trimmer (corded)500W700W5.0–6.5A class
Dehumidifier (50-pint)500W520WES median 488W + nameplates 515–545W
Boiler circulator (Taco 007)80W85Wofficial submittal 0.74A
Sump pump M98 (½HP)1,080WUnconfirmed W9.4A alone does not establish actual watts

Overstated — you overpay for capacity you don't need (corrected down)

ApplianceCopied tableAuditedBasis
LED bulb (60W-equiv)13W9WENERGY STAR certified median (n=219)
LED bulb (100W-equiv)23W15WENERGY STAR certified median (n=40)
LED bulb (40W-equiv)10W5WENERGY STAR certified median (n=38)
CFL bulb (60W-equiv)18W14Wenergy.gov consumer chart
Box fan (20")200W90WLasko official 65–90W
Gas clothes dryer1,800W400Wmetered 250–400W (old value = circuit capacity, not draw)
Curling iron150W85WHot Tools 85W / Conair 125W
Humidifier (evaporative)200W80WAIRCARE 80W / Honeywell 60W
Can opener150W100Wretail class 50–100W
Printer (inkjet)100W40WEpson official ~12W printing; 100W was laser-class
Cable box (set-top)35W25WDISH energy table 22–28W
Sewage pump M2671,200W / 1,080WUnconfirmed WCurrent rating is not actual real watts
Mini-split startup (12K)4,200W / 2,240 from MCAUnconfirmedMCA-derived startup assumption withdrawn
Starlink Performance130W90Wcurrent spec sheet 75–100W (130W = retired model)

The full audited chart (130 appliances)

Generated from the same verified library that powers every calculator on this site — it cannot drift. “Surge basis” tells you whether the startup figure is a manufacturer-published LRA, a physics-checked compressor value, or a class estimate.

Refrigerators & Freezers (8)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
Refrigerator (top-freezer, ~16 cu ft) 125 W Estimated start 1,200 W physics-checked 8
Refrigerator (bottom-freezer, ~20 cu ft) 190 W Estimated start 1,200 W physics-checked 8
Refrigerator (side-by-side, ~24 cu ft) 220 W Estimated start 1,200 W physics-checked 8
Freezer (upright, ~15 cu ft) 155 W Estimated start 1,200 W physics-checked 8
Freezer (chest, ~15 cu ft) 90 W Estimated start 1,200 W physics-checked 8
Freezer (compact, ~4.5 cu ft) 90 W Estimated start 1,200 W physics-checked 8
Refrigerator (freezerless, ~16 cu ft) 100 W Estimated start 1,200 W physics-checked 8
Portable 12V Fridge/Freezer (Dometic CFX3 45 class) 100 W Estimated start 300 W class estimate (3× rule) 5

Kitchen (18)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
Microwave Oven 1,000 W No extra startup allowance modeled — 0.25
Coffee Maker 1,000 W No extra startup allowance modeled — 0.1
Toaster 1,100 W No extra startup allowance modeled — 0.05
Dishwasher (with heated dry) 1,200 W Startup unconfirmed — 0.6
Toaster Oven 1,225 W No extra startup allowance modeled — 0.15
Range Hood 25 W Estimated start 75 W class estimate (3× rule) 1
Blender 500 W Startup unconfirmed — 0.1
Espresso Machine 1,300 W No extra startup allowance modeled — 0.2
Garbage Disposal (1/2 HP) 750 W Estimated start 2,250 W class estimate (3× rule) 0.05
Electric Kettle 1,200 W No extra startup allowance modeled — 0.15
Stand Mixer 300 W Startup unconfirmed — 0.1
Electric Can Opener 100 W Estimated start 300 W class estimate (3× rule) 0.02
Electric Oven / Stove 3,000 W No extra startup allowance modeled — 0.5
Air Fryer (4 qt basket) 1,550 W No extra startup allowance modeled — 0.5
Slow Cooker (7 qt) 250 W No extra startup allowance modeled — 4
Rice Cooker (Micom 5.5-cup) 610 W No extra startup allowance modeled — 0.5
Electric Pressure Cooker (6 qt, Instant Pot class) 1,000 W No extra startup allowance modeled — 0.4
Induction Cooktop (portable single burner) 1,800 W No extra startup allowance modeled — 1

Heating, Cooling & Air Conditioning (26)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
Portable Space Heater 1,500 W No extra startup allowance modeled — 4
Furnace Fan (1/2 HP blower) 750 W Estimated start 2,250 W class estimate (3× rule) 4
Ceiling Fan 35 W Estimated start 105 W class estimate (3× rule) 8
Dehumidifier (50-pint) 520 W Estimated start 1,560 W class estimate (3× rule) 3
Electric Blanket (double) 100 W No extra startup allowance modeled — 8
Window Fan 150 W Estimated start 450 W class estimate (3× rule) 8
Whole House Fan 500 W Estimated start 1,500 W class estimate (3× rule) 4
Window AC (5,000 BTU) 400 W Estimated start 1,200 W class estimate (3× rule) 8
Window AC (8,000 BTU) 550 W Estimated start 1,650 W class estimate (3× rule) 8
Window AC (10,000 BTU) 700 W Estimated start 2,100 W class estimate (3× rule) 8
Window AC (12,000 BTU) 800 W Estimated start 2,400 W class estimate (3× rule) 8
Room Air Purifier 25 W Startup unconfirmed — 24
Bathroom Exhaust Fan 16 W Startup unconfirmed — 2
Box Fan 90 W Estimated start 270 W class estimate (3× rule) 8
Humidifier 80 W Startup unconfirmed — 10
Central AC (2-ton, 24,000 BTU) Unconfirmed Published start 8,740 VA nameplate LRA 8
In-line Duct Fan 42 W Estimated start 126 W class estimate (3× rule) 3
Window AC (6,000 BTU) 450 W Estimated start 1,350 W class estimate (3× rule) 8
Central AC (3-ton, 36,000 BTU) Unconfirmed Published start 17,710 VA nameplate LRA 8
Central AC (4-ton, 48,000 BTU) Unconfirmed Published start 25,070 VA nameplate LRA 8
Portable AC (10,000 BTU, single-hose) 1,130 W Estimated start 3,390 W class estimate (3× rule) 8
Pellet Stove (Harman P43 reference) 200 W Startup unconfirmed — 12
Hydronic Circulator Pump (Taco 007 class) 85 W Estimated start 255 W class estimate (3× rule) 10
Ductless Mini-Split (12,000 BTU heat pump) 1,400 W Startup unconfirmed inverter topology; check profile 8
RV Rooftop AC (13,500 BTU) 1,800 W Published start 7,800 VA nameplate LRA 8
Window AC (12,000 BTU, inverter/Most Efficient) 750 W No extra startup allowance modeled inverter topology; check profile 8

Water & Pumps (12)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
Deep Well Water Pump 750 W Estimated start 2,250 W class estimate (3× rule) 0.5
Electric Water Heater (40 gal) 5,000 W No extra startup allowance modeled — 1
Sump Pump (1/3 HP) Unconfirmed Estimated start 3,300 W class estimate (3× rule) 0.3
Submersible Well Pump (1/2 HP, 240V) 670 W Published start 7,400 VA nameplate LRA 0.5
Tankless Water Heater (electric) 18,000 W No extra startup allowance modeled — 0.5
Heat Pump Water Heater (heat-pump mode) 700 W Estimated start 2,100 W class estimate (3× rule) 4.5
Submersible Well Pump (3/4 HP, 240V) 940 W Published start 9,360 VA nameplate LRA 0.5
Submersible Well Pump (1 HP, 240V) 1,210 W Published start 11,200 VA nameplate LRA 0.5
Submersible Well Pump (1.5 HP, 240V) 1,710 W Published start 15,230 VA nameplate LRA 0.5
RV 12V Water Pump (Shurflo 4008 class) 90 W Estimated start 270 W class estimate (3× rule) 0.5
Sump Pump (1/2 HP, high-capacity) Unconfirmed Estimated start 3,240 W class estimate (3× rule) 0.3
Sewage Ejector Pump (1/2 HP, basement) Unconfirmed Estimated start 3,250 W class estimate (3× rule) 0.3

Laundry (7)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
Clothes Washer 500 W Estimated start 1,500 W class estimate (3× rule) 0.7
Hair Dryer 1,500 W No extra startup allowance modeled — 0.1
Clothes Dryer (electric) 3,000 W Startup unconfirmed — 0.75
Clothes Iron 1,400 W No extra startup allowance modeled — 0.25
Vacuum Cleaner 1,200 W Estimated start 3,600 W class estimate (3× rule) 0.15
Clothes Dryer (gas) 400 W Estimated start 1,200 W class estimate (3× rule) 0.75
Curling Iron 85 W No extra startup allowance modeled — 0.25

Electronics & Office (31)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
Laptop Computer 50 W No extra startup allowance modeled — 8
Desktop PC (under load) 120 W No extra startup allowance modeled — 4
TV (32-inch LED) 32 W No extra startup allowance modeled — 5
TV (43-inch LED) 63 W No extra startup allowance modeled — 5
TV (50-inch LED) 72 W No extra startup allowance modeled — 5
TV (65-inch LED) 117 W No extra startup allowance modeled — 5
TV (75-inch LED) 151 W No extra startup allowance modeled — 5
Tablet 10 W No extra startup allowance modeled — 6
Clock Radio 10 W No extra startup allowance modeled — 24
Computer Monitor (24-inch LED) 15 W No extra startup allowance modeled — 4
Home Stereo System 200 W Startup unconfirmed — 2
Starlink Standard (Gen 3) 90 W No extra startup allowance modeled — 24
Starlink Performance (Gen 3) 90 W No extra startup allowance modeled — 24
Blu-ray / DVD Player 15 W No extra startup allowance modeled — 2
Cable / Satellite Box 25 W No extra startup allowance modeled — 4
Satellite Dish Receiver 25 W No extra startup allowance modeled — 5
Game Console 150 W No extra startup allowance modeled — 3
Electric Shaver 15 W No extra startup allowance modeled — 0.1
Router + Modem 15 W No extra startup allowance modeled — 24
Printer (inkjet) 40 W No extra startup allowance modeled — 0.5
Desktop PC (gaming) 500 W No extra startup allowance modeled — 4
Phone / Smartphone Charger 10 W No extra startup allowance modeled — 6
TV (55-inch LED) 93 W No extra startup allowance modeled — 5
Computer Monitor (27-inch LED) 18 W No extra startup allowance modeled — 4
All-in-One PC 60 W No extra startup allowance modeled — 4
EV Charger (Level 2) 7,200 W No extra startup allowance modeled — 3
Starlink Standard Actuated (Gen 2) 60 W No extra startup allowance modeled — 24
Starlink Mini 30 W No extra startup allowance modeled — 24
Security Camera System (4x PoE cameras + NVR) 45 W No extra startup allowance modeled — 24
Laser Printer (workgroup class) 495 W No extra startup allowance modeled — 0.5
Powered PA Speaker (12 in — QSC K12.2 class) Unconfirmed No extra startup allowance modeled — 4

Medical Devices (3)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
CPAP Machine (ResMed AirSense 11, with humidifier) 56 W Operating peak 73W — 8
Home Oxygen Concentrator (5 LPM class) 275 W Estimated start 825 W class estimate (3× rule) 24
Compressor Nebulizer (Omron CompAir class) 10 W Estimated start 30 W class estimate (3× rule) 1

Power Tools & Workshop (18)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
Pool Pump (variable-speed, high) 800 W Estimated start 2,400 W class estimate (3× rule) 6
Sewing Machine 100 W Estimated start 300 W class estimate (3× rule) 0.5
Circular Saw (7-1/4 inch) 1,500 W Estimated start 4,500 W class estimate (3× rule) 0.25
Drill (1/2 inch) 850 W Estimated start 2,550 W class estimate (3× rule) 0.25
Drill (1/4 inch) 250 W Estimated start 750 W class estimate (3× rule) 0.25
Electric Chainsaw (12 inch) 1,100 W Estimated start 3,300 W class estimate (3× rule) 0.25
Band Saw (14 inch) Unconfirmed Estimated start 4,200 W class estimate (3× rule) 0.5
Belt Sander (3 inch) 1,000 W Estimated start 3,000 W class estimate (3× rule) 0.25
Disc Sander (9 inch) 1,200 W Estimated start 3,600 W class estimate (3× rule) 0.25
Hedge Trimmer 450 W Estimated start 1,350 W class estimate (3× rule) 0.5
String Trimmer (electric) 700 W Estimated start 2,100 W class estimate (3× rule) 0.5
Treadmill 650 W Estimated start 1,950 W class estimate (3× rule) 0.5
Garage Door Opener (1/2 HP, belt/chain) 350 W Estimated start 1,050 W class estimate (3× rule) 0.1
Shop Vacuum (6 gallon, 3.5 peak HP) 900 W Estimated start 2,700 W class estimate (3× rule) 0.25
Air Compressor (4.2 gal twin-stack) Unconfirmed Estimated start 4,400 W class estimate (3× rule) 0.5
Electric Pressure Washer (2,000 PSI class) Unconfirmed Estimated start 5,250 W class estimate (3× rule) 0.5
MIG Welder (140A, 120V — Hobart Handler 140 class) 2,500 W Startup unconfirmed — 0.5
MIG Welder (210A class, 240V — Hobart Handler 210 MVP) 4,600 W Startup unconfirmed — 0.5

Lighting (7)

ApplianceRunningPeak / startup profileSurge basisHrs/day*
LED Bulb (60W equivalent) 9 W No extra startup allowance modeled — 5
LED Bulb (100W equivalent) 15 W No extra startup allowance modeled — 5
Incandescent Bulb (100W) 100 W No extra startup allowance modeled — 5
CFL Bulb (60W equivalent) 14 W No extra startup allowance modeled — 5
LED Bulb (40W equivalent) 5 W No extra startup allowance modeled — 5
Halogen Bulb (40W) 40 W No extra startup allowance modeled — 5
Incandescent Bulb (50W) 50 W No extra startup allowance modeled — 5

* Typical duty cycle from DOE / ENERGY STAR usage data — the number that determines daily energy (Wh), not the nameplate watts. Rows marked “cross-checked class estimate” in our library are representative class values confirmed against multiple sources, not single-model nameplates.

Sizing a battery station or generator? The chart is the ingredient list — the calculator is the recipe: it adds your devices, applies the startup physics and matches real products. High startup load from an AC or pump? The soft-start screening tool shows what a kit changes.

Frequently asked questions

Why do appliance wattage charts disagree with each other?

Most charts online copy the same decades-old table. We machine-checked its values against U.S. DOE data, the ENERGY STAR certified-product APIs and manufacturer spec sheets, and found it wrong in both directions: power tools understated by 40–60% (your station trips offline mid-cut) and modern LED lighting overstated by 50–150% (you buy twice the battery you need). This chart shows the audited values, each traceable to a source.

What is startup surge and why does one column say LRA?

The power profile separates motor-start demand, operating peaks, explicit no-extra-startup assumptions and unknown data. LRA times voltage gives apparent power in VA, not real watts. We label estimates separately and do not confirm a VA load by comparing it directly with a W-only station rating. Missing startup data is unconfirmed, not zero.

How was this chart verified?

Every row carries a source and evidence labels. Some are class estimates or have missing real-watt or startup evidence; those figures are marked unconfirmed rather than presented as measured values. ENERGY STAR aggregates can be recomputed from the official APIs; manufacturer references come from spec sheets and manuals. Source review is not a tested station-and-appliance pairing.