Appliance wattage chart — audited, not copied
130 appliances with running watts and startup surge, every value traceable to U.S. DOE data, the ENERGY STAR certified-product datasets, or manufacturer spec sheets. Before publishing it, we machine-checked the internet's most-copied wattage table against those sources and found 25 corrections and withdrawals. They are documented below — judge the data, not the marketing.
The audit: what the copied table gets wrong
Prefer the long version? Read the story of this audit — how the table broke, why both error directions cost money, and what we did differently.
The wattage table most sites republish traces back decades. Checking it against primary sources produced corrections in both directions — and both cost you money: understated startup loads make a generator or battery station trip offline the first time a motor starts; overstated loads make you buy twice the capacity you need.
Understated — your station trips offline (corrected up)
| Appliance | Copied table | Audited | Basis |
|---|---|---|---|
| Refrigerators & freezers (7 models) | startup surge 375–660W | 1,200W | compressor LRA physics (nameplate reports, 9–12× RLA) |
| RV rooftop AC (13.5K) | startup 7,200W | 7,800VA | Dometic install manual LRA 68A |
| Garbage disposal (½HP) | 450W | 750W | InSinkErator Badger 5 spec 6.3A |
| Espresso machine (pump class) | 800W | 1,300W | De'Longhi 1100W / Breville 1560W official |
| Circular saw (corded 7¼") | 900W | 1,500W | 15A rated class (Makita/DeWalt) |
| Corded drill (½") | 750W | 850W | 7.0–7.8A rated class |
| Band saw (14") | 1,100W / 1,400W | Unconfirmed W | Current-only conversion withdrawn |
| String trimmer (corded) | 500W | 700W | 5.0–6.5A class |
| Dehumidifier (50-pint) | 500W | 520W | ES median 488W + nameplates 515–545W |
| Boiler circulator (Taco 007) | 80W | 85W | official submittal 0.74A |
| Sump pump M98 (½HP) | 1,080W | Unconfirmed W | 9.4A alone does not establish actual watts |
Overstated — you overpay for capacity you don't need (corrected down)
| Appliance | Copied table | Audited | Basis |
|---|---|---|---|
| LED bulb (60W-equiv) | 13W | 9W | ENERGY STAR certified median (n=219) |
| LED bulb (100W-equiv) | 23W | 15W | ENERGY STAR certified median (n=40) |
| LED bulb (40W-equiv) | 10W | 5W | ENERGY STAR certified median (n=38) |
| CFL bulb (60W-equiv) | 18W | 14W | energy.gov consumer chart |
| Box fan (20") | 200W | 90W | Lasko official 65–90W |
| Gas clothes dryer | 1,800W | 400W | metered 250–400W (old value = circuit capacity, not draw) |
| Curling iron | 150W | 85W | Hot Tools 85W / Conair 125W |
| Humidifier (evaporative) | 200W | 80W | AIRCARE 80W / Honeywell 60W |
| Can opener | 150W | 100W | retail class 50–100W |
| Printer (inkjet) | 100W | 40W | Epson official ~12W printing; 100W was laser-class |
| Cable box (set-top) | 35W | 25W | DISH energy table 22–28W |
| Sewage pump M267 | 1,200W / 1,080W | Unconfirmed W | Current rating is not actual real watts |
| Mini-split startup (12K) | 4,200W / 2,240 from MCA | Unconfirmed | MCA-derived startup assumption withdrawn |
| Starlink Performance | 130W | 90W | current spec sheet 75–100W (130W = retired model) |
The full audited chart (130 appliances)
Generated from the same verified library that powers every calculator on this site — it cannot drift. “Surge basis” tells you whether the startup figure is a manufacturer-published LRA, a physics-checked compressor value, or a class estimate.
Refrigerators & Freezers (8)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| Refrigerator (top-freezer, ~16 cu ft) | 125 W | Estimated start 1,200 W | physics-checked | 8 |
| Refrigerator (bottom-freezer, ~20 cu ft) | 190 W | Estimated start 1,200 W | physics-checked | 8 |
| Refrigerator (side-by-side, ~24 cu ft) | 220 W | Estimated start 1,200 W | physics-checked | 8 |
| Freezer (upright, ~15 cu ft) | 155 W | Estimated start 1,200 W | physics-checked | 8 |
| Freezer (chest, ~15 cu ft) | 90 W | Estimated start 1,200 W | physics-checked | 8 |
| Freezer (compact, ~4.5 cu ft) | 90 W | Estimated start 1,200 W | physics-checked | 8 |
| Refrigerator (freezerless, ~16 cu ft) | 100 W | Estimated start 1,200 W | physics-checked | 8 |
| Portable 12V Fridge/Freezer (Dometic CFX3 45 class) | 100 W | Estimated start 300 W | class estimate (3× rule) | 5 |
Kitchen (18)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| Microwave Oven | 1,000 W | No extra startup allowance modeled | — | 0.25 |
| Coffee Maker | 1,000 W | No extra startup allowance modeled | — | 0.1 |
| Toaster | 1,100 W | No extra startup allowance modeled | — | 0.05 |
| Dishwasher (with heated dry) | 1,200 W | Startup unconfirmed | — | 0.6 |
| Toaster Oven | 1,225 W | No extra startup allowance modeled | — | 0.15 |
| Range Hood | 25 W | Estimated start 75 W | class estimate (3× rule) | 1 |
| Blender | 500 W | Startup unconfirmed | — | 0.1 |
| Espresso Machine | 1,300 W | No extra startup allowance modeled | — | 0.2 |
| Garbage Disposal (1/2 HP) | 750 W | Estimated start 2,250 W | class estimate (3× rule) | 0.05 |
| Electric Kettle | 1,200 W | No extra startup allowance modeled | — | 0.15 |
| Stand Mixer | 300 W | Startup unconfirmed | — | 0.1 |
| Electric Can Opener | 100 W | Estimated start 300 W | class estimate (3× rule) | 0.02 |
| Electric Oven / Stove | 3,000 W | No extra startup allowance modeled | — | 0.5 |
| Air Fryer (4 qt basket) | 1,550 W | No extra startup allowance modeled | — | 0.5 |
| Slow Cooker (7 qt) | 250 W | No extra startup allowance modeled | — | 4 |
| Rice Cooker (Micom 5.5-cup) | 610 W | No extra startup allowance modeled | — | 0.5 |
| Electric Pressure Cooker (6 qt, Instant Pot class) | 1,000 W | No extra startup allowance modeled | — | 0.4 |
| Induction Cooktop (portable single burner) | 1,800 W | No extra startup allowance modeled | — | 1 |
Heating, Cooling & Air Conditioning (26)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| Portable Space Heater | 1,500 W | No extra startup allowance modeled | — | 4 |
| Furnace Fan (1/2 HP blower) | 750 W | Estimated start 2,250 W | class estimate (3× rule) | 4 |
| Ceiling Fan | 35 W | Estimated start 105 W | class estimate (3× rule) | 8 |
| Dehumidifier (50-pint) | 520 W | Estimated start 1,560 W | class estimate (3× rule) | 3 |
| Electric Blanket (double) | 100 W | No extra startup allowance modeled | — | 8 |
| Window Fan | 150 W | Estimated start 450 W | class estimate (3× rule) | 8 |
| Whole House Fan | 500 W | Estimated start 1,500 W | class estimate (3× rule) | 4 |
| Window AC (5,000 BTU) | 400 W | Estimated start 1,200 W | class estimate (3× rule) | 8 |
| Window AC (8,000 BTU) | 550 W | Estimated start 1,650 W | class estimate (3× rule) | 8 |
| Window AC (10,000 BTU) | 700 W | Estimated start 2,100 W | class estimate (3× rule) | 8 |
| Window AC (12,000 BTU) | 800 W | Estimated start 2,400 W | class estimate (3× rule) | 8 |
| Room Air Purifier | 25 W | Startup unconfirmed | — | 24 |
| Bathroom Exhaust Fan | 16 W | Startup unconfirmed | — | 2 |
| Box Fan | 90 W | Estimated start 270 W | class estimate (3× rule) | 8 |
| Humidifier | 80 W | Startup unconfirmed | — | 10 |
| Central AC (2-ton, 24,000 BTU) | Unconfirmed | Published start 8,740 VA | nameplate LRA | 8 |
| In-line Duct Fan | 42 W | Estimated start 126 W | class estimate (3× rule) | 3 |
| Window AC (6,000 BTU) | 450 W | Estimated start 1,350 W | class estimate (3× rule) | 8 |
| Central AC (3-ton, 36,000 BTU) | Unconfirmed | Published start 17,710 VA | nameplate LRA | 8 |
| Central AC (4-ton, 48,000 BTU) | Unconfirmed | Published start 25,070 VA | nameplate LRA | 8 |
| Portable AC (10,000 BTU, single-hose) | 1,130 W | Estimated start 3,390 W | class estimate (3× rule) | 8 |
| Pellet Stove (Harman P43 reference) | 200 W | Startup unconfirmed | — | 12 |
| Hydronic Circulator Pump (Taco 007 class) | 85 W | Estimated start 255 W | class estimate (3× rule) | 10 |
| Ductless Mini-Split (12,000 BTU heat pump) | 1,400 W | Startup unconfirmed | inverter topology; check profile | 8 |
| RV Rooftop AC (13,500 BTU) | 1,800 W | Published start 7,800 VA | nameplate LRA | 8 |
| Window AC (12,000 BTU, inverter/Most Efficient) | 750 W | No extra startup allowance modeled | inverter topology; check profile | 8 |
Water & Pumps (12)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| Deep Well Water Pump | 750 W | Estimated start 2,250 W | class estimate (3× rule) | 0.5 |
| Electric Water Heater (40 gal) | 5,000 W | No extra startup allowance modeled | — | 1 |
| Sump Pump (1/3 HP) | Unconfirmed | Estimated start 3,300 W | class estimate (3× rule) | 0.3 |
| Submersible Well Pump (1/2 HP, 240V) | 670 W | Published start 7,400 VA | nameplate LRA | 0.5 |
| Tankless Water Heater (electric) | 18,000 W | No extra startup allowance modeled | — | 0.5 |
| Heat Pump Water Heater (heat-pump mode) | 700 W | Estimated start 2,100 W | class estimate (3× rule) | 4.5 |
| Submersible Well Pump (3/4 HP, 240V) | 940 W | Published start 9,360 VA | nameplate LRA | 0.5 |
| Submersible Well Pump (1 HP, 240V) | 1,210 W | Published start 11,200 VA | nameplate LRA | 0.5 |
| Submersible Well Pump (1.5 HP, 240V) | 1,710 W | Published start 15,230 VA | nameplate LRA | 0.5 |
| RV 12V Water Pump (Shurflo 4008 class) | 90 W | Estimated start 270 W | class estimate (3× rule) | 0.5 |
| Sump Pump (1/2 HP, high-capacity) | Unconfirmed | Estimated start 3,240 W | class estimate (3× rule) | 0.3 |
| Sewage Ejector Pump (1/2 HP, basement) | Unconfirmed | Estimated start 3,250 W | class estimate (3× rule) | 0.3 |
Laundry (7)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| Clothes Washer | 500 W | Estimated start 1,500 W | class estimate (3× rule) | 0.7 |
| Hair Dryer | 1,500 W | No extra startup allowance modeled | — | 0.1 |
| Clothes Dryer (electric) | 3,000 W | Startup unconfirmed | — | 0.75 |
| Clothes Iron | 1,400 W | No extra startup allowance modeled | — | 0.25 |
| Vacuum Cleaner | 1,200 W | Estimated start 3,600 W | class estimate (3× rule) | 0.15 |
| Clothes Dryer (gas) | 400 W | Estimated start 1,200 W | class estimate (3× rule) | 0.75 |
| Curling Iron | 85 W | No extra startup allowance modeled | — | 0.25 |
Electronics & Office (31)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| Laptop Computer | 50 W | No extra startup allowance modeled | — | 8 |
| Desktop PC (under load) | 120 W | No extra startup allowance modeled | — | 4 |
| TV (32-inch LED) | 32 W | No extra startup allowance modeled | — | 5 |
| TV (43-inch LED) | 63 W | No extra startup allowance modeled | — | 5 |
| TV (50-inch LED) | 72 W | No extra startup allowance modeled | — | 5 |
| TV (65-inch LED) | 117 W | No extra startup allowance modeled | — | 5 |
| TV (75-inch LED) | 151 W | No extra startup allowance modeled | — | 5 |
| Tablet | 10 W | No extra startup allowance modeled | — | 6 |
| Clock Radio | 10 W | No extra startup allowance modeled | — | 24 |
| Computer Monitor (24-inch LED) | 15 W | No extra startup allowance modeled | — | 4 |
| Home Stereo System | 200 W | Startup unconfirmed | — | 2 |
| Starlink Standard (Gen 3) | 90 W | No extra startup allowance modeled | — | 24 |
| Starlink Performance (Gen 3) | 90 W | No extra startup allowance modeled | — | 24 |
| Blu-ray / DVD Player | 15 W | No extra startup allowance modeled | — | 2 |
| Cable / Satellite Box | 25 W | No extra startup allowance modeled | — | 4 |
| Satellite Dish Receiver | 25 W | No extra startup allowance modeled | — | 5 |
| Game Console | 150 W | No extra startup allowance modeled | — | 3 |
| Electric Shaver | 15 W | No extra startup allowance modeled | — | 0.1 |
| Router + Modem | 15 W | No extra startup allowance modeled | — | 24 |
| Printer (inkjet) | 40 W | No extra startup allowance modeled | — | 0.5 |
| Desktop PC (gaming) | 500 W | No extra startup allowance modeled | — | 4 |
| Phone / Smartphone Charger | 10 W | No extra startup allowance modeled | — | 6 |
| TV (55-inch LED) | 93 W | No extra startup allowance modeled | — | 5 |
| Computer Monitor (27-inch LED) | 18 W | No extra startup allowance modeled | — | 4 |
| All-in-One PC | 60 W | No extra startup allowance modeled | — | 4 |
| EV Charger (Level 2) | 7,200 W | No extra startup allowance modeled | — | 3 |
| Starlink Standard Actuated (Gen 2) | 60 W | No extra startup allowance modeled | — | 24 |
| Starlink Mini | 30 W | No extra startup allowance modeled | — | 24 |
| Security Camera System (4x PoE cameras + NVR) | 45 W | No extra startup allowance modeled | — | 24 |
| Laser Printer (workgroup class) | 495 W | No extra startup allowance modeled | — | 0.5 |
| Powered PA Speaker (12 in — QSC K12.2 class) | Unconfirmed | No extra startup allowance modeled | — | 4 |
Medical Devices (3)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| CPAP Machine (ResMed AirSense 11, with humidifier) | 56 W | Operating peak 73W | — | 8 |
| Home Oxygen Concentrator (5 LPM class) | 275 W | Estimated start 825 W | class estimate (3× rule) | 24 |
| Compressor Nebulizer (Omron CompAir class) | 10 W | Estimated start 30 W | class estimate (3× rule) | 1 |
Power Tools & Workshop (18)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| Pool Pump (variable-speed, high) | 800 W | Estimated start 2,400 W | class estimate (3× rule) | 6 |
| Sewing Machine | 100 W | Estimated start 300 W | class estimate (3× rule) | 0.5 |
| Circular Saw (7-1/4 inch) | 1,500 W | Estimated start 4,500 W | class estimate (3× rule) | 0.25 |
| Drill (1/2 inch) | 850 W | Estimated start 2,550 W | class estimate (3× rule) | 0.25 |
| Drill (1/4 inch) | 250 W | Estimated start 750 W | class estimate (3× rule) | 0.25 |
| Electric Chainsaw (12 inch) | 1,100 W | Estimated start 3,300 W | class estimate (3× rule) | 0.25 |
| Band Saw (14 inch) | Unconfirmed | Estimated start 4,200 W | class estimate (3× rule) | 0.5 |
| Belt Sander (3 inch) | 1,000 W | Estimated start 3,000 W | class estimate (3× rule) | 0.25 |
| Disc Sander (9 inch) | 1,200 W | Estimated start 3,600 W | class estimate (3× rule) | 0.25 |
| Hedge Trimmer | 450 W | Estimated start 1,350 W | class estimate (3× rule) | 0.5 |
| String Trimmer (electric) | 700 W | Estimated start 2,100 W | class estimate (3× rule) | 0.5 |
| Treadmill | 650 W | Estimated start 1,950 W | class estimate (3× rule) | 0.5 |
| Garage Door Opener (1/2 HP, belt/chain) | 350 W | Estimated start 1,050 W | class estimate (3× rule) | 0.1 |
| Shop Vacuum (6 gallon, 3.5 peak HP) | 900 W | Estimated start 2,700 W | class estimate (3× rule) | 0.25 |
| Air Compressor (4.2 gal twin-stack) | Unconfirmed | Estimated start 4,400 W | class estimate (3× rule) | 0.5 |
| Electric Pressure Washer (2,000 PSI class) | Unconfirmed | Estimated start 5,250 W | class estimate (3× rule) | 0.5 |
| MIG Welder (140A, 120V — Hobart Handler 140 class) | 2,500 W | Startup unconfirmed | — | 0.5 |
| MIG Welder (210A class, 240V — Hobart Handler 210 MVP) | 4,600 W | Startup unconfirmed | — | 0.5 |
Lighting (7)
| Appliance | Running | Peak / startup profile | Surge basis | Hrs/day* |
|---|---|---|---|---|
| LED Bulb (60W equivalent) | 9 W | No extra startup allowance modeled | — | 5 |
| LED Bulb (100W equivalent) | 15 W | No extra startup allowance modeled | — | 5 |
| Incandescent Bulb (100W) | 100 W | No extra startup allowance modeled | — | 5 |
| CFL Bulb (60W equivalent) | 14 W | No extra startup allowance modeled | — | 5 |
| LED Bulb (40W equivalent) | 5 W | No extra startup allowance modeled | — | 5 |
| Halogen Bulb (40W) | 40 W | No extra startup allowance modeled | — | 5 |
| Incandescent Bulb (50W) | 50 W | No extra startup allowance modeled | — | 5 |
* Typical duty cycle from DOE / ENERGY STAR usage data — the number that determines daily energy (Wh), not the nameplate watts. Rows marked “cross-checked class estimate” in our library are representative class values confirmed against multiple sources, not single-model nameplates.
Sizing a battery station or generator? The chart is the ingredient list — the calculator is the recipe: it adds your devices, applies the startup physics and matches real products. High startup load from an AC or pump? The soft-start screening tool shows what a kit changes.
Frequently asked questions
Why do appliance wattage charts disagree with each other?
Most charts online copy the same decades-old table. We machine-checked its values against U.S. DOE data, the ENERGY STAR certified-product APIs and manufacturer spec sheets, and found it wrong in both directions: power tools understated by 40–60% (your station trips offline mid-cut) and modern LED lighting overstated by 50–150% (you buy twice the battery you need). This chart shows the audited values, each traceable to a source.
What is startup surge and why does one column say LRA?
The power profile separates motor-start demand, operating peaks, explicit no-extra-startup assumptions and unknown data. LRA times voltage gives apparent power in VA, not real watts. We label estimates separately and do not confirm a VA load by comparing it directly with a W-only station rating. Missing startup data is unconfirmed, not zero.
How was this chart verified?
Every row carries a source and evidence labels. Some are class estimates or have missing real-watt or startup evidence; those figures are marked unconfirmed rather than presented as measured values. ENERGY STAR aggregates can be recomputed from the official APIs; manufacturer references come from spec sheets and manuals. Source review is not a tested station-and-appliance pairing.