Find your setup
UNDERSTAND THE NUMBERS

How long will a battery station run your refrigerator?

First check whether it can start the compressor. Then estimate elapsed runtime from usable battery energy and the fridge’s daily energy use.

A rechargeable lantern on an apartment dining table at dusk.
Illustrative scene · plan for your own appliances and operating conditions.
Quick answer
A typical 16 cu ft refrigerator uses about 1,000Wh per day. On a 1,000Wh battery station, expect 18-24 hours of runtime. The critical constraint is the 1,200W startup surge from the compressor — not the battery capacity.

The reference case

Our refrigerator (top-freezer, ~16 cu ft) uses a modeled 1,000Wh per day: 125W × 8 operating hours. An electrically compatible 1,000Wh station provides about 19.2 hours of daily-average runtime with an 80% usable-energy allowance.

Startup rating must also cover the modeled 1,200 W peak. Capacity alone cannot establish that.

The math, step by step.

  1. Use the appliance’s running power and actual daily operating hours to estimate daily Wh.
  2. Divide daily Wh by 24 to estimate average power over a complete daily cycle.
  3. Multiply station capacity by 0.8 once, then divide by average power.
  4. Check continuous output, startup rating and voltage before treating that runtime as feasible.
Nameplate batteryUsable energy (80%)Daily-average runtimeElectrical screen
300Wh240Wh5.8 hoursStill required for every size
500Wh400Wh9.6 hoursStill required for every size
1,000Wh800Wh19.2 hoursStill required for every size
2,000Wh1,600Wh38.4 hoursStill required for every size
3,600Wh2,880Wh69.1 hoursStill required for every size

These are energy-only examples, not recommendations for a particular station. Hot weather, opening the door, defrost cycles, inverter idle draw and the actual appliance model change results. For a short outage, compressor cycles may not resemble a complete day’s average.

Why a small station may fail immediately.

The library’s modeled startup requirement is 1,200 W while running power is 125W. A 600W surge rating fails that screen even if the battery could theoretically store several hours of energy. Our runtime chart suppresses runtime for incompatible products.

Plan a full day.

The reference case needs 1,250Wh of nameplate capacity after the 25% allowance. The candidates below meet that target in the shared recommendation engine. Runtime in each card is compressor powered on-time, so do not confuse it with elapsed daily-cycle runtime.

Anker

Anker SOLIX F1500

1,536WhNameplate capacity
1,800WContinuous output
2,400WPublished surge

120V · LFP · 19.8 kg · No expansion capacity recorded

One load at a time · powered operating hours

  • Refrigerator (top-freezer, ~16 cu ft)9.8 h

80% usable battery energy. These are powered on-hours, not elapsed duty-cycle runtime. Confirm startup duration, outlets and equipment compatibility.

~$599Recorded base-unit price · extras excluded · recorded 2026-10-15
Check official price ↗
View manufacturer source →
EcoFlow

EcoFlow DELTA 3 Max

2,048WhNameplate capacity
2,400WContinuous output
4,800WPublished surge

120V · LFP · 20.3 kg · No expansion capacity recorded

One load at a time · powered operating hours

  • Refrigerator (top-freezer, ~16 cu ft)13.1 h

80% usable battery energy. These are powered on-hours, not elapsed duty-cycle runtime. Confirm startup duration, outlets and equipment compatibility.

~$899Recorded base-unit price · extras excluded · recorded 2026-10-14
Check official price ↗
View manufacturer source →
EcoFlow

EcoFlow DELTA 3 Max Plus

2,048WhNameplate capacity
3,000WContinuous output
6,000WPublished surge

120V · LFP · Unpublished · Expansion ceiling: 10,000Wh

One load at a time · powered operating hours

  • Refrigerator (top-freezer, ~16 cu ft)13.1 h

80% usable battery energy. These are powered on-hours, not elapsed duty-cycle runtime. Confirm startup duration, outlets and equipment compatibility.

~$1,149Recorded base-unit price · extras excluded · recorded 2026-10-14
Check official price ↗
View manufacturer source →

What about solar or a week-long outage?

A larger expanded system may store enough energy for several days. Solar can add energy during an outage, but it requires a separate daily production and charging plan. Weather, shade, charging limits, losses and the shortest useful day all matter. No indefinite-runtime guarantee is included in the battery-only estimates here.