Apartment backup power: start with a realistic operating plan.
Choose what must stay on, how long it will run, and how you will recharge. A portable battery can power selected plug-in devices without permanent panel work; check the equipment instructions and your building’s rules.
Adjust the fridge and communications plan →

Two starting schedules, calculated from the shared library
These are reference plans, not measurements of your apartment. The refrigerator’s four compressor-hours are a cycling assumption within a twelve-hour outage, not twelve hours of continuous running. Adjust both watts and operating hours in the calculator.
| Plan | Load energy | Nameplate battery target | Continuous-output target |
|---|---|---|---|
| Eight-hour communications plan | 232 Wh | 290 Wh | 60 W |
| Twelve-hour fridge and communications plan | 792 Wh | 990 Wh | 200 W |
Eight-hour communications plan
Router for 8h, two phone chargers for 2h each, two LED bulbs for 4h each.
The capacity target includes the shared 25% allowance. Output, voltage and startup checks are separate; a battery with enough Wh may still fail the electrical screen. Edit this exact schedule →
Twelve-hour fridge and communications plan
Fridge compressor operating for 4h within 12h, router for 12h, two phone chargers for 2h each and two LED bulbs for 4h each.
The capacity target includes the shared 25% allowance. Output, voltage and startup checks are separate; a battery with enough Wh may still fail the electrical screen. Edit this exact schedule →
What a small battery can actually promise
A 245Wh battery contains an estimated 196 usable Wh under our shared assumption. A 15W router alone gives about 13.1 hours by energy arithmetic. That is before separate station idle consumption; adding lights, chargers or medical equipment reduces the remaining energy. A generic “15–20 hours for everything” promise is not supported.
Check the charging circuit separately
A station’s output watts do not tell you its wall-charging input. Check the manual’s AC input limit, any pass-through mode and everything else sharing the circuit. A large charging input can consume most of a shared circuit’s capacity even when the battery is powering only small devices.
Food temperature and medical equipment need their own checks
A runtime estimate does not certify food safety. Keep refrigerator doors closed and follow FoodSafety.gov’s outage guidance for temperature and time limits.
For CPAP or other medical equipment, use the exact machine and settings, including humidification and heated tubing. Verify the power path and backup arrangement with the equipment supplier. Our CPAP shortlist describes one reference machine; it is not a guarantee for another setup.
Recharging and storage
Follow the station manufacturer’s storage and charging instructions. Solar energy through a window depends on glazing, orientation, shading and weather; do not assume a fixed daily yield. The schedules above assume no recharging during the outage.
Frequently asked questions
Can a small battery run my router, lights and CPAP all night?
Calculate the combined schedule. A 245Wh battery has 196Wh under our 80% usable-energy assumption: at 15W, a router alone has an energy-only estimate of 13.1 hours before separate station idle draw. Additional loads shorten that estimate. CPAP requirements depend on the exact machine, settings and approved supply.
Does a fridge runtime estimate tell me whether my food is safe?
No. Food safety depends on temperature and time. Keep doors closed, monitor temperature and follow FoodSafety.gov guidance. Battery operation cannot be converted into extra guaranteed food-safe hours.
Can I charge and use a station on a shared apartment circuit?
Check maximum AC charging input, pass-through behavior and other loads on the circuit. The station’s output rating alone does not establish the charging-circuit demand. Follow its manual and building rules.