Battery Bank Calculator

Batteries = ⌈Your Wh need ÷ per-battery Wh⌉

A 3,600Wh need needs 3 × 1,200Wh batteries (3.6 kWh bank). Sizing is a ceiling division — partial batteries don't exist. The trap is chemistry: a 1,200Wh lead-acid battery delivers only ~600Wh usable, so the same need would take 6 of them.

Updated · Calculated examples; assumptions and safety notes below.

Your numbers, clearly calculated
Batteries needed (nominal)3 batteries
Nominal bank capacity3,600 Wh
Usable if lead-acid (~50% of nominal)1,800 Wh

Common needs vs bank size

<tr><th scope="col">Need</th><th scope="col">Lithium batteries</th><th scope="col">Lead-acid batteries</th></tr>
Batteries needed at 1,200Wh per unit, by chemistry. Lithium (LiFePO4) usable ≈ 90%; lead-acid ≈ 50%.
Fridge overnight (~1,000Wh)12
CPAP + lights + phone (~700Wh)12
Work day: laptop, router, tools (~2,400Wh)34
Multi-day essentials (~5,000Wh)59

Assumes 1,200Wh (100Ah 12V) units. Our sizing calculator applies chemistry-specific usable factors automatically across verified appliances.

FAQ

Can I mix old and new batteries in a bank?

Not recommended. An aged cell drags the whole bank: in series it caps capacity; in parallel it steals charge. Match chemistry, age, capacity and preferably batch.

Why is lead-acid only 50% usable?

Discharging a lead-acid below ~50% state of charge causes sulfation that permanently cuts capacity, so half the label is reserved. Lithium (LiFePO4) has no such knee — 80–100% is normal. This single fact often makes lithium cheaper per usable Wh despite the higher sticker price.