Inverter Size Calculator
Cover continuous load with 25% headroom, and the surge — whichever is higher
A 900W continuous load with a 2,700W startup surge needs an inverter rated ~2,700W or higher. Two different limits must both pass: the continuous rating covers sustained running draw (with headroom for efficiency loss and long sessions), and the surge rating covers the largest motor start — a compressor or pump pulls 2–6× its running power for a second or two at startup.
Updated · Calculated examples; assumptions and safety notes below.
Worked examples
| Fridge + router + lights | 300W | 1,200W (compressor) | 1,200W |
| Well pump (½HP class) | 1,000W | 3,000W | 3,000W |
| Office: PC + monitors | 450W | 700W | ~565W |
| Continuous load only (no motor) | 2,500W | n/a | 3,125W |
Surge figures here are planning examples. Real startup demand must come from each appliance's locked-rotor or inrush data — our appliance library records verified surge figures per device, and pure-sine output is required by most electronics and motors.
FAQ
What size inverter do I need for a fridge?
Sum the fridge's running watts and its startup surge. An Energy Star fridge runs ~125W but starts at ~1,200W: the surge is the binding number, so a 1,200W+ pure-sine inverter covers it. Our refrigerator guide has the verified figures.
Why 25% headroom on the continuous load?
Inverters lose efficiency as loads approach their rating (heat, fan throttle), and real loads drift above nameplate. Sizing at exactly 100% of measured load runs the inverter at its thermal edge indefinitely — the 25% margin keeps it in the efficient, quiet band.
Does a bigger inverter waste power?
Slightly — larger units have higher idle draw. Size for your real load plus headroom, not "as big as possible". A 3,000W inverter idling for a 100W load wastes meaningful stored energy overnight.